Balun Designs

Model 1116d - 1-54 MHz, 5kW - Optimized for Low Frequencies


Model 1116d - 1-54 MHz, 5kW - Optimized for Low Frequencies

Calculated at checkout

Product Description

This Isolation balun is an identical design to the Model 1115d with one key exception. The material utilized for the two stacked cores is optimized for the lower HF bands and provides exceptional choking impedance at these frequencies. In excess of 5000 ohms choking impedance on 160m and over 6300 ohms on 80m and 40 meters. The 1116d even generates over 4000 ohms of choking impedance on 20 meters

No other design can provide this level of isolation and choking at these lower frequencies.  Note that although optimized for lower frequencies, this balun also provides very good choking at higher frequencies and can be used up through 30MHz. 

Please go to the Accessories category for additional RF connector types and mounting options.

 "Hi Bob, the balun/choke (ed note model 1116dt) is working out great on the ZS6BKW antenna, I only need to use the tuner on 80/75 and 15 meters plus now it seems that the power company has made changes on correcting the problems with the power lines and my noise level has dropped by allot (S9+10 to S1). As a test case I can very easily get on the roof to change the balun. I tried the DX engineering one I borrowed and on 14.201 there was a plasma TV signal at S7, then I went back to your balun and the signal dropped down between S1-2 so the choking of your balun does work much better and I have been having a blast. Worked VK's on long path on 75 at gray line once this year and I only run 1Kw plus VK's and ZL's in the morning on that band when conditions are good. On 40 meters it works really good as well, worked the TX3X on SSB the first day they operated that band on that mode with maybe 3-4 calls and the other day I was on 20 meters and heard a FR4 calling CQ all by himself and nobody came back to him so I called him and he came back with a 57, I was only running 100w".

 Testing shows SWR remains below 1.05 across the entire HF band, transformation is perfectly flat, return loss is between 60-80 dbmw and choking impedance is maximized at over 6k ohms on the low HF frequencies. Please click on the graphs shown below to view the complete test results.

  choking-impedance.jpg  1116d Scan_thumb.jpg
Click to Enlarge

Tests run utilizing AIM-4170uhf Network Analyzer and a precision non-inductive 50 ohm load



 It must be pointed out that a 1:1 balun should never be used on the second harmonic of a half-wave center-fed dipole when using coax feedline (like an 80 meter dipole being used on 40 meters). The impedance can be as great as 5,000 ohms creating very high voltages which can bring about voltage breakdown and/or excessive heating. This exception ONLY applies to coax fed HALF WAVE CENTER FED DIPOLES WHEN USING A 1:1 BALUN AT THE FEEDPOINT.  This caution does not apply to fan dipoles, doublets fed with ladder line or dipoles that utilize loading coils to create resonance on the bands in use.


Noise Reduction

While the most common advice is to improve the station's RF ground, the root of the problem is in the poor isolation of the feedline from antenna currents. If your goal is to reduce feedline radiation and improve reception by reducing noise, feedline isolation baluns are an excellent choice. Adding an additonal isolation balun at the point where the feedline exits the near field area of the antenna will substantially reduce unwanted feedline radiation and reception of EMI without the need for improved station grounding. 


  Core Material   Custom mix ferrite by Fair Rite Products optimized for low frequencies.
  Cores are coated and sealed for long term durability.
  Winding Type   Stacked dual core, coaxial wound 1:1 current balun provides larger effective core area.
  Winding Material   Mil Spec 50 ohm coax rated 19kW @ 1MHz, 9kW @ 10 MHz & 4kW @ 50 MHz.
  Silver flashed braid and center conductor with solid Teflon dielectric.
  Power Rating   1 to 31 MHz - 5kW, 10kW intermittent, 31 to 54MHz - 3kW
  All ratings at resonance. High SWR will reduce power handling ability.
  Useable Frequency   1 to 54 MHz
  Insertion Loss   Less than .02db
  Connectors   SO-239 connectors are silver plated with Teflon insulation.
  Studs and eyebolts are 1/4 inch.
  Alternate connectors and Mounting Options are available in the Accessories section.
  Hardware   All Stainless Steel
  Enclosure Type   NEMA rated 4x marine grade junction box for outdoor installations.
  Cover has neoprene gasket for weatherproof integrity.
  Dimensions   4x4x2 inches for main body of unit
  Additional Info   Very high efficiency (98-99%). 
  Will not heat up or saturate at like many of the "less expensive" designs.

Installation Notes